V80 Fuser Film Sleeve

Fuser system error Xerox printer. How to solve the Xerox printer fuser system error?

Fuser system error Xerox 7855

Fuser system error Xerox 7845

How do I fix Xerox fuser error?

Model number: Xerox WorkCentre 7525/7530/7535/7545/7556/7830/7835/7845/7855 series

Problem description: “Fuser System Error” is displayed on the screen

  • Fuser Failure analysis:

When the Xerox printer prompts “Fuser system error”, it may involve the following situations:

1. the motor is faulty;

2. there is a problem with the motor drive board;

3. the MCU circuit board is faulty;

4. there is a problem with the fuser itself (010-330);

5. the external voltage is unstable.

  • Solution:

For the above possible causes of the problem, we can take corresponding measures.

First, we need to confirm whether the voltage of the fuser is consistent with the current voltage used. In addition, when the external voltage is unstable, it may also cause the display of “Fixing system error”.

Second, when turning on the machine, we can judge whether the left fuser unit is working properly based on the sound. If no sound is heard or there is an abnormal sound, it may be a problem with the motor. At this time, we need to remove the fuser unit and check whether the rotation resistance of the gears on both sides is normal to determine whether the gears are damaged. If the gear is damaged, it needs to be replaced or cleaned, and the appropriate amount of gear oil needs to be added to restore its normal load.

If the gear is not damaged, then the problem may be with the fixing film. Excessive rotational resistance of the fuser film sleeve may also cause such errors. In this case, we need to remove the fixing film sleeve for comprehensive cleaning. During the cleaning process, it should be handled with care, and it is recommended to use a glasses cloth and a small amount of alcohol for cleaning.

Finally, it should be emphasized that the fixing unit is an important part of the printer, so when performing any maintenance operations, it should be carried out under the guidance of professionals to ensure safety and effectiveness.