Introduction
Gradation Adjustment is an important image-quality calibration procedure for Konica Minolta bizhub color multifunction printers, including the C368, C308, and C258.
Its purpose is to calibrate the gradation response of each printing color channel so that light areas, intermediate tones, and dark areas are reproduced more accurately.
For color machines, the adjustment involves four independent color channels:
- C – Cyan
- M – Magenta
- Y – Yellow
- K – Black
For monochrome machines, only the black channel is involved.
Gradation Adjustment may be required after replacing major imaging components, such as drum units, developer units, or the transfer belt, or when the machine produces uneven color density, poor grayscale transitions, or visible gradation steps.
However, Gradation Adjustment should not be confused with Color Registration Adjustment. Gradation Adjustment corrects tonal reproduction, while Color Registration Adjustment addresses color alignment and registration problems.
This guide explains the preparation requirements, operating procedures, adjustment modes, result evaluation, and common mistakes when performing Gradation Adjustment on the Konica Minolta bizhub C368, C308, and C258.
Key Takeaways
- Gradation Adjustment calibrates the tonal response of the C/M/Y/K color channels.
- Run Image Stabilization Only before starting Gradation Adjustment.
- Do not proceed if Image Stabilization Only reports NG.
- Use Printer (600dpi) for normal printing calibration in most routine situations.
- Printer (1200dpi) is intended for high-resolution printing calibration and, according to the described procedure, automatically outputs two A4 sheets.
- Place the test chart face down on the original glass and cover it with 10 clean blank A4 sheets before scanning.
- Complete three adjustment cycles in total.
- Conv. Values are the key values to check when evaluating the adjustment results.
- If the results remain outside the specified ranges after repeated attempts, investigate the imaging hardware instead of continuing calibration indefinitely.
1. What Is Gradation Adjustment?
Gradation Adjustment calibrates the tonal response of the printer’s color channels.
In practical terms, it helps the machine reproduce different image densities more accurately, from light highlights to dark areas.
For example:
- Light gray areas should remain light.
- Intermediate gray tones should transition smoothly.
- Dark areas should reproduce sufficient density.
- Color transitions should not show obvious steps or unevenness.
1.1 Four Color Channels in a Color Printer
A color Konica Minolta machine uses four separate printing channels:
| Channel | Color | Function |
|---|---|---|
| C | Cyan | Blue-green color reproduction |
| M | Magenta | Red-purple color reproduction |
| Y | Yellow | Yellow color reproduction |
| K | Black | Black and grayscale reproduction |
Each channel has its own gradation response.
The printing system uses the CMYK color model, which is based on subtractive color mixing. This is different from the RGB additive color model used by computer displays.
A computer monitor produces colors using red, green, and blue light, while a printer reproduces colors using cyan, magenta, yellow, and black toner.
Gradation Adjustment calibrates the printer’s tonal reproduction; it does not convert the machine’s CMYK printing system into RGB.
1.2 When Should You Perform Gradation Adjustment?
Common situations include:
- After replacing a drum unit.
- After replacing developer or carrier.
- After replacing the transfer belt.
- When printed images show uneven tonal transitions.
- When grayscale output shows visible gradation steps.
- When performing image-quality calibration after maintenance.
The actual need for calibration depends on the component replaced and the machine’s condition.
2. Important Difference: Gradation Adjustment vs. Color Registration Adjustment
These two adjustment procedures solve different image-quality problems.
| Adjustment | Main Purpose | Typical Symptoms |
|---|---|---|
| Gradation Adjust | Corrects tonal density and gradation response | Uneven gray levels, poor gradients, incorrect tonal density |
| Color Registration Adjust | Corrects alignment between color channels | Color misregistration, color shadows, shifted or doubled color edges |
| Max Image Density Adj. | Adjusts maximum image density | Maximum density requires further adjustment after gradation calibration |
Important: If the machine has color registration problems, such as color shadows or misaligned color edges, do not expect Gradation Adjustment to solve them.
Perform the appropriate Color Registration Adjustment separately.
For P21/P22 color registration-related warnings, resolve the registration issue first according to the applicable service procedure before proceeding with Gradation Adjustment.
3. Preparation Before Gradation Adjustment
Before starting the procedure, confirm that the machine and its imaging components are in suitable working condition.
3.1 Check Consumables and Imaging Hardware
The following components should be functioning normally:
- Drum units
- Developer units and carrier
- IDC density sensors
- Transfer belt and related imaging components
If a major imaging component is defective or its condition is abnormal, Gradation Adjustment may not produce reliable results.
3.2 Confirm the Machine Is Ready
Before starting:
- Allow the machine to complete warm-up.
- Make sure there is no paper jam.
- Close all machine doors and covers.
- Confirm that the machine is not displaying unresolved imaging-related warnings.
3.3 Warning Codes That Must Be Checked First
According to the supplied repair notes, the following warnings are important when preparing for Gradation Adjustment:
| Warning Code | Related Component or Condition | Recommended Action |
|---|---|---|
| P-5 | IDC density sensor abnormality | Inspect the IDC sensor and related circuit |
| P-6 | Cyan drum-related fault | Check the cyan imaging unit |
| P-7 | Magenta drum-related fault | Check the magenta imaging unit |
| P-8 | Yellow drum-related fault | Check the yellow imaging unit |
| P-9 | Black drum-related fault | Check the black imaging unit |
| P-28 | Carrier aging or related developer condition | Check the developer and carrier condition |
| P21/P22 | Color registration-related warning | Resolve the registration problem first |
For P-5, P-6, P-7, P-8, P-9, and P-28, the Start button may be unavailable or locked, preventing the adjustment from starting.
P21/P22 may not necessarily lock the Start button. However, according to the supplied procedure, the color registration problem should be resolved before running Gradation Adjustment.
Always confirm the exact warning-code definition and required repair procedure against the service documentation for the specific machine.
3.4 Mandatory Preliminary Step: Image Stabilization Only
Before performing Gradation Adjustment, run:
Image Stabilization Only
Check the result before continuing.
- OK: The machine passes the preliminary image stabilization check. Continue with Gradation Adjustment.
- NG: Stop and investigate the cause before proceeding.
An NG result may indicate problems involving the developer, drum units, IDC sensors, or other imaging-related components.
Do not use Gradation Adjustment as a substitute for repairing an existing imaging-system fault.
3.5 Prepare the Paper and Original Glass
Prepare the following materials:
- A4 plain copy paper.
- One clean test-chart printing surface.
- 10 additional clean blank A4 sheets.
- A clean original glass.
Important paper-feed requirement: Print the test chart using the paper tray. Do not use the manual feed tray for this procedure.
According to the supplied repair procedure, manual-feed paper positioning and feed timing may cause the test chart to be positioned incorrectly, affecting the calibration scan.
Also clean the original glass thoroughly. Toner contamination, dust, and other marks can interfere with the scanning process.
The 10 blank A4 sheets are placed on top of the test chart during scanning to help prevent toner show-through from affecting the scan readings.
4. How to Perform Gradation Adjustment
4.1 Enter the Gradation Adjust Menu
Access the machine’s adjustment menu using the appropriate service or administrator procedure.
The described menu path is:
System Settings → Expert Adjustment → Gradation Adjust
The exact menu path and access permissions may vary with firmware and machine configuration.
4.2 Select the Adjustment Mode
Three adjustment options are available in the described procedure.
| Mode | Purpose | Paper Output |
|---|---|---|
| Printer (600dpi) | Normal printing calibration | A4 |
| Printer (1200dpi) | High-resolution printing calibration | Automatically outputs two A4 sheets |
| Copy | Calibration for copy-image reproduction | Depends on the selected procedure |
Printer (600dpi)
This is the recommended starting choice for routine printing calibration.
It is suitable for normal office printing and common document output.
Printer (1200dpi)
This mode is intended for high-resolution printing calibration.
According to the described procedure, there is no A3 selection in this mode. The machine automatically outputs two A4 sheets.
Copy
Select this option when the issue concerns copy-image reproduction, such as abnormal gradation in copied images.
Choose the adjustment mode according to the actual problem rather than running every mode without a specific reason.
4.3 Print the Gradation Test Chart
After selecting the required adjustment mode:
- Confirm the selected paper size.
- Press Start.
- Allow the machine to print the gradation test chart.
Use the paper tray as specified in the preparation procedure.
4.4 Place the Test Chart on the Original Glass
This is one of the most important steps.
- Open the original cover.
- Place the printed test chart face down on the original glass.
- Position the chart according to the direction shown on the machine display.
- Place 10 clean blank A4 sheets on top of the test chart.
- Close the original cover.
The 10 blank sheets help reduce the effect of toner show-through during scanning.
Make sure the original glass is clean and the test chart is correctly positioned.
4.5 Scan the Test Chart
After positioning the test chart:
- Press Start again.
- The machine scans the printed color patches.
- The system calculates the adjustment values for the C/M/Y/K channels.
Wait until the scanning and calculation process is completed.
4.6 Repeat the Adjustment Three Times in Total
The described procedure requires three complete adjustment cycles.
Each cycle consists of:
Print test chart → Place chart on original glass → Add 10 blank A4 sheets → Scan chart
Repeat this complete process until three cycles have been completed.
After the third cycle, open Gradation Adjust and review the results.
Do not confuse three total cycles with three additional repetitions after the first cycle.
5. How to Read Gradation Adjustment Results
After completing the adjustment, the machine displays two important values:
- Adj. Values
- Conv. Values
5.1 Adj. Values
Adj. Values represent the adjustment values calculated during the procedure.
They show the adjustment information generated by the calibration process.
5.2 Conv. Values
Conv. Values are the key comparison values for evaluating whether the gradation adjustment has reached the specified range.
According to the supplied procedure, the following limits are used:
| Measurement Area | Target Value | Acceptable Range |
|---|---|---|
| Dark | 0 | ±100 |
| Highlight | 0 | ±60 |
In practical terms:
- Dark values should fall between -100 and +100.
- Highlight values should fall between -60 and +60.
The C, M, Y, and K channels should all meet the applicable limits.
Important: Do not judge the adjustment by looking at Adj. Values alone. Check the Conv. Values for the specified result evaluation.
These numerical limits are based on the supplied repair notes and should be confirmed against the applicable service documentation and firmware version before being treated as universal specifications.
6. Troubleshooting Abnormal Gradation Adjustment Results
Not every calibration attempt will produce acceptable values.
The following table summarizes the main conditions and recommended actions.
| Observed Result | Possible Cause or Condition | Recommended Action |
|---|---|---|
| Values exceed the limits after one adjustment sequence | Calibration has not yet reached the acceptable range | Repeat the adjustment sequence |
| Values become acceptable after the second sequence | Calibration is successful | Stop; further repetitions are unnecessary |
| Dark or Highlight values remain outside the limits after repeated sequences | Imaging density or hardware condition may be abnormal | Stop repeated gradation adjustment and check Max Image Density Adj. |
| All values display 0 | Scanning or reading failure is suspected | Restart the machine and repeat the procedure after checking the setup |
| Values remain unacceptable after four complete sequences | A hardware or imaging-system problem may exist | Stop calibration and investigate the hardware |
6.1 Values Exceed the Limits After the First Sequence
If the first adjustment sequence does not produce acceptable Conv. Values, repeat the complete adjustment procedure.
The supplied procedure allows a maximum of four complete sequences.
If the values become acceptable after the second sequence, there is no need to continue.
6.2 Dark or Highlight Values Remain Outside the Limits
If the values remain outside the acceptable range after repeated adjustment sequences, the next step described in the repair procedure is:
Max Image Density Adj. – Maximum Image Density Adjustment
This should be considered only after Gradation Adjustment has been attempted and the results remain unacceptable.
Do not immediately start with Max Image Density Adjustment without first completing the appropriate gradation calibration.
6.3 All Values Display 0
If all adjustment values display 0, suspect a scanning or reading problem.
Recommended checks:
- Turn off the machine using the main power switch.
- Wait at least 10 seconds.
- Turn the machine back on.
- Recheck the original glass for contamination.
- Confirm the test chart is correctly positioned.
- Make sure the 10 blank A4 sheets are placed on top of the chart.
- Check the IDC sensor condition if the problem continues.
- Repeat the adjustment procedure.
If the machine continues to display zero values, investigate the scanning and image-density detection system rather than repeatedly running the same procedure without inspection.
6.4 Results Remain Unacceptable After Four Complete Sequences
If four complete adjustment sequences fail to bring the Conv. Values within the specified range, stop repeating the calibration.
Further repetitions are unlikely to solve an underlying hardware problem.
Prioritize inspection of:
- Developer and carrier condition
- Drum wear or imaging-unit problems
- IDC sensor contamination or failure
- Transfer belt and transfer-related problems
- Other imaging-system abnormalities
The exact cause must be determined through component inspection and appropriate diagnostic procedures.
7. Common Mistakes During Gradation Adjustment
Incorrect preparation can lead to unreliable calibration results.
The following mistakes should be avoided.
Mistake 1: Using the Manual Feed Tray
Do not use manual feed for the test chart in the described procedure.
Incorrect paper positioning or feed timing may cause the printed chart to be positioned differently from the expected scanning coordinates.
Use the specified paper tray instead.
Mistake 2: Scanning Without the 10 Blank A4 Sheets
Placing only the printed test chart on the original glass may allow toner show-through to affect the scan.
Place 10 clean blank A4 sheets on top of the chart as specified.
Mistake 3: Ignoring Original Glass Contamination
Toner particles, dust, and marks on the original glass can interfere with scanning.
Clean the glass before beginning the adjustment.
Mistake 4: Starting Gradation Adjustment When Image Stabilization Reports NG
An NG result indicates that the machine has not passed the preliminary image stabilization check.
Investigate the imaging-system problem first.
Running Gradation Adjustment without resolving the underlying condition may produce unreliable results.
Mistake 5: Ignoring Imaging-Related Warning Codes
If the machine displays P-5, P-6, P-7, P-8, P-9, or P-28, check the relevant component before attempting the adjustment.
Do not try to bypass a locked Start button.
Mistake 6: Looking for an A3 Option in Printer (1200dpi)
According to the described procedure, Printer (1200dpi) does not provide an A3 selection.
The machine automatically outputs two A4 sheets.
Mistake 7: Continuing Calibration After Four Failed Sequences
Repeated calibration cannot reliably compensate for worn drums, aged carrier, defective IDC sensors, or transfer-system problems.
After four unsuccessful complete sequences, stop and diagnose the hardware.
8. Final Image Quality Inspection
After Gradation Adjustment is completed successfully, print a sample page and inspect the image quality.
Check the following:
Grayscale reproduction
- Gray transitions should be smooth.
- There should be no obvious steps or breaks between tonal levels.
- Light gray areas should not appear unnecessarily dark.
- Dark areas should have sufficient density.
Color reproduction
- Colors should appear reasonably uniform.
- There should be no obvious color imbalance.
- Light color areas should not show excessive background contamination.
If color edges are misaligned or show color shadows, remember that this is a registration issue rather than a gradation issue.
Perform the appropriate Color Registration Adjustment separately.
9. Correct Adjustment Order: Gradation Adjust vs. Max Image Density Adj.
These two procedures have different purposes and should not be treated as interchangeable.
| Sequence | Adjustment | Main Purpose |
|---|---|---|
| 1 | Gradation Adjust | Calibrate tonal response and gradation |
| 2 | Max Image Density Adj. | Adjust maximum image density when further correction is required |
The recommended order in the supplied procedure is:
First: Gradation Adjustment
Complete the gradation calibration and check the Conv. Values.
Second: Max Image Density Adjustment
Consider this procedure if repeated Gradation Adjustment attempts still produce unacceptable dark or highlight values.
Do not start with maximum image density adjustment without first completing the appropriate gradation calibration.
10. Quick Reference: Gradation Adjustment Checklist
Use this checklist when performing Gradation Adjustment on the Konica Minolta C368, C308, or C258.
Before Starting
- ☐ Check drum and developer condition.
- ☐ Check carrier condition.
- ☐ Confirm IDC sensor status.
- ☐ Confirm that the machine has completed warm-up.
- ☐ Make sure there are no paper jams.
- ☐ Close all doors and covers.
- ☐ Check for relevant warning codes.
- ☐ Run Image Stabilization Only.
- ☐ Confirm that the result is OK.
- ☐ Prepare A4 plain paper.
- ☐ Clean the original glass.
- ☐ Prepare 10 clean blank A4 sheets.
During Adjustment
- ☐ Enter Gradation Adjust.
- ☐ Select Printer (600dpi), Printer (1200dpi), or Copy as required.
- ☐ Print the test chart using the paper tray.
- ☐ Place the chart face down on the original glass.
- ☐ Follow the direction shown on the display.
- ☐ Place 10 blank A4 sheets on top.
- ☐ Close the original cover.
- ☐ Start scanning.
- ☐ Complete three adjustment cycles in total.
After Adjustment
- ☐ Check Adj. Values.
- ☐ Check Conv. Values.
- ☐ Confirm Dark values are within ±100.
- ☐ Confirm Highlight values are within ±60.
- ☐ Confirm all applicable C/M/Y/K channels meet the limits.
- ☐ Print a sample page.
- ☐ Check grayscale transitions and color uniformity.
- ☐ If results remain unacceptable after four sequences, stop and inspect the hardware.
Frequently Asked Questions
Q1: What does Gradation Adjustment do on a Konica Minolta C368?
Gradation Adjustment calibrates the tonal response of the printer’s color channels. It helps the machine reproduce highlights, intermediate tones, and dark areas more accurately.
Q2: When should I perform Gradation Adjustment?
It may be required after replacing drum units, developer or carrier, or the transfer belt. It is also useful when printed images show uneven gradation, poor grayscale transitions, or abnormal tonal reproduction.
Q3: What is the difference between Printer (600dpi) and Printer (1200dpi)?
Printer (600dpi) is intended for routine printing calibration. Printer (1200dpi) is intended for high-resolution printing calibration. According to the described procedure, the 1200dpi mode automatically outputs two A4 sheets and does not offer an A3 selection.
Q4: Why must I place 10 blank A4 sheets on top of the test chart?
The blank sheets help reduce the effect of toner show-through during scanning, improving the reliability of the chart-reading process.
Q5: How many times should I perform Gradation Adjustment?
The described standard procedure consists of three complete adjustment cycles.
If the results remain outside the specified limits, additional complete sequences may be attempted, up to four sequences in total according to the supplied repair notes.
Stop once the values meet the specified limits.
Q6: What are the acceptable Conv. Values?
According to the supplied procedure:
- Dark: 0 ±100
- Highlight: 0 ±60
All applicable C/M/Y/K channels should fall within the specified ranges.
Q7: What should I do if all Gradation Adjustment values are 0?
A zero reading may indicate that the test chart was not read correctly.
Check the original glass, chart positioning, and blank paper arrangement. Power-cycle the machine by turning off the main power and waiting at least 10 seconds before restarting. If the problem persists, investigate the IDC sensor and related detection system.
Q8: Should I perform Max Image Density Adjustment before Gradation Adjustment?
No. According to the described procedure, perform Gradation Adjustment first.
Max Image Density Adjustment is the next step to consider when repeated gradation calibration attempts do not produce acceptable results.
Q9: Does Gradation Adjustment solve color registration problems?
No. Gradation Adjustment corrects tonal reproduction. Color Registration Adjustment corrects alignment between color channels.
If the printed image shows color shadows or shifted color edges, investigate color registration separately.
Conclusion
Gradation Adjustment is an important calibration procedure for maintaining consistent image quality on Konica Minolta bizhub C368, C308, and C258 machines.
Successful calibration depends not only on selecting the correct adjustment mode but also on preparing the machine properly, running Image Stabilization Only, using the correct paper feed method, positioning the test chart accurately, and evaluating the Conv. Values correctly.
The most important points to remember are:
- Run Image Stabilization Only and confirm OK before starting.
- Use the paper tray to print the test chart.
- Place the chart face down on the original glass with 10 blank A4 sheets on top.
- Complete three adjustment cycles in total.
- Check Dark and Highlight Conv. Values.
- Stop repeated calibration after four unsuccessful complete sequences and investigate the imaging hardware.
A correct Gradation Adjustment procedure can improve tonal consistency, but it cannot repair defective drums, aged carrier, faulty IDC sensors, or other underlying imaging-system problems.
Technical disclaimer: This article is based on the supplied repair procedure for the Konica Minolta bizhub C368/C308/C258. Menu paths, warning-code definitions, adjustment limits, and firmware behavior should be verified against the applicable service documentation before performing maintenance. Procedures and specifications may differ between models and firmware versions.
Leave A Comment